InstallationandOperationManual(REVH) PVI6500/PVI7500

9
Another important safety feature that has the ability to isolate the inverter from the grid is the DC ground fault detection and
interrupt(GFDI)circuit.ThePVarray’sgroundedconductorisbondedtogroundinsidetheinverterthroughtheGFDIfuse(andmust
notbebondedtogroundatany other
pointoutsideofthe inverter).
PVI65007500Description
Fig.1.2PVI6500/7500FeaturesDiagram

(1)ACknockouts
(2) PVarraygrou nd faultinterrupt(GFDI)fuse (inside wiringbox)
(3) CombinedDC/ACd isconnec tswitch
(4) DCknockouts
(5) Heatsink 
(6) RS485interface s
(7) LCDdisplay
(8) LEDindicatorsofbasicoperatingstatus
(9) Invert erSerialNumber
(10)Detachable wiringbox
(11)Quick mount
wallplate(behin dunit)
9
8
7
6
1
4
3
5
10
11
2(inside)