Candy PV 640 X Manual de usuario Pagina 23

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 72
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 22
23
• SETTING THE IDLE FLAME
If you have changed the type of gas, it is important to verify the flame stability at the
minimum regulation.
«Gaining access to the by-pass screw»
To gain access to hob burner by-pass screws, remove the knobs from the control panel.
By-pass screw of the hob burner
Never loosen
the others screws !
REGULATING THE MINIMUM FLAME ON THE HOB BURNER
a) Natural gas :
. simply loosen the screw.
. switch on the burner and turn the knob to minimum.
. Turn the by-pass screw until a low flame is visible. Turn the control knob from
minimum to maximum position to check that it is satisfactory.
b) Butane-propane gas :
The by-pass screw should be screwed fully home, without being locked.
!
INSTALLATION: «REGULATING THE FLAME»